Kevin IGBT based Cyber UPS provides Pure Sine Wave output whereas output of home UPS of other brands gets badly distorted especially on normally encountered loads like Compact Fluorescent Lamp (CFL), Tube Lights, Motors, Coolers, Computers, etc. This type of distorted waveform is very harmful for all your sophisticated and sensitive electronic appliances. Hence, Kevin IGBT Cyber UPS is the preferred choice. It deliverspure power with reliable performance and at a reasonable price.
Zero Battery Consumption in ‘Switch Off ’ & ‘Mains Off ‘ Conditions
Pure Sine Wave even with Computer & Compact Fluorescent Lamp (CFL) Load
Lower Battery Discharge as compared to a conventional Home UPS/Inverter
Technical Specifications*
Description
650VA
850VA
1450VA
Output Voltage at No Load
220V±5V AC
Output Frequency
50.0 Hz ± 1.0Hz
Output Wave Form
Pure Sine Wave
Nominal Battery Voltage
12V DC
24V DC
Max. No Load Current @ Fully Charged Battery
1.2A
1.2A
Battery Low Alarm
10.6V ± 0.2V DC
21V ± 0.4V DC
Battery Low Protection
10.4V ± 0.2V DC
20.8V ± 0.4V DC
Peak Efficiency
>85%
>85%
No Load Current @ Switch Off/ Mains Off
OA (Zero Amp)
THD (Total Hormonic Distortion )
< =3% @ resistive load
Full Load Battery Current
40A±2A
52A±2A
46A±2A
UPS Mode
Input Voltage Range
180V to 260V Ac ± 5V Ac
Maximum Changeover Time
<=10ms
Normal Mode
Input Voltage Range
100V to 280V Ac ± 10V Ac
Input Voltage Range For Charging
180V to 280V Ac ± 10V Ac
Maximum Changeover Time
<=10ms
Charging Mode
Charging Current @ 220 V AC (NC)
7A+/-1A
9A+/-1A
Charging Current @ 220 V AC (HC)
10A+/-1A
9A+/-1A
Boost Charging Voltage
14.2 ± 0.2 VDC
28.4 ± 0.2 VDC
Float Charging Voltage
13.7 ± 0.2 VDC
27.4 ± 0.2 VDC
Protections
Protections
Battery Voltage Low (4 Auto Retries).
Over Load (6 Auto Retries)
Battery Over Charge, Over Temperature, Short Circuit (One Retry), Battery Deep Discharge Protection
Displays
Displays
AC Mains Voltage, UPS ON/OFF
Short Circuit, Overload, Battery Low, Load %
Mains ON/OFF,
Battery Charging/Charged/Low
Weight and Dimensions
With Packing WXDXH in mm
390x340x130
Without Packing WXDXH in mm
310x260x90
Net Weight
3.4 Kg
4.25 Kg
Gross Weight
4.2Kg
5.10Kg
General
Communication
4Pin Serial Interface for Calibration of Various Parameters
Operating Temprature Range
0Deg. To 45 Deg.
Relative Humidity
0-90% Non Condensing
Load Chart *
Load
650VA
850VA
1450VA
T.V
1
-
-
1
-
-
1
-
-
Tube Light
4
4
-
6
5
-
10
8
-
Fan
3
4
-
4
5
-
7
9
-
Computers**
-
-
4
-
-
5
-
-
10
Note: The Charging Current can be increased / decreased using the unique and “first-in- class”
On Site Charging Rate Control OSCRCTM features.