Contact Us Career
     
 
 
Products




 
 
 
 
DSP SINE WAVE HOME UPS
 
 
Kevin IGBT Based Cyber UPS provides Pure Sine Wave output. whereas output of Home UPS of other brands gets badly distorted especially on normal loads like Compact Fluorescent Lamp, Tube Lights, Motors, Coolers & Computers etc.. This type of Distorted Waveform is very Harmful for all your Sophisticated Electronics Appliances. Hence, Kevin IGBT Cyber UPS is the Preferred choice. It delivers Pure Power, with Reliable Performance and at a Reasonable Price.
15% Extra Back – up
Wide charging Window ( 110VAC to 280VAC)
Compact Design & Light Weight
20%- 25 % Saving in Electricity
Compatibility With Generator
OSCRCTM Technology Based Charger
External DC Fuse (Easy to Replace)
Capableof Charging/Recovering Deep-Discharged Battery
Zero Battery Consumption in ‘Switch Off ’ & ‘Mains Off ‘ Conditions
Pure Sine Wave even with Computer & Compact Fluorescent Lamp (CFL) Load
Lower Battery Discharge as compared to that with conventional Home UPS/Inverter

 
 
Technical Specifications*

Description 650VA 850VA 1450VA
Output Voltage at No Load
220V±5V AC
Output Frequency
50.0 Hz ± 1.0Hz
Output Wave Form
Pure Sine Wave
Nominal Battery Voltage
12V DC 24V DC
Max. No Load Current @ Fully Charged Battery
1.2A 1.2A
Battery Low Alarm
10.6V ± 0.2V  DC 21V ± 0.4V  DC
Battery Low Protection
10.4V ± 0.2V  DC 20.8V ± 0.4V  DC
Peak Efficiency
>85% >85%
No Load Current @ Switch Off/ Mains Off
OA (Zero Amp)
THD (Total Harmonic Distortion )
< =3% @ resistive load
Full Load Battery Current
40A±2A 52A±2A 46A±2A
  UPS Mode
Input Voltage Range
180V to 260V Ac ± 5V Ac
Maximum Changeover Time
<=10ms
  Normal Mode
Input Voltage Range
100V to 280V Ac ± 10V Ac
Input Voltage Range For Charging
180V to 280V Ac ± 10V Ac
Maximum Changeover Time
<=10ms
  Charging Mode
Charging Current @ 220 V AC (NC)
7A+/-1A   9A+/-1A
Charging Current @ 220 V AC (HC)
10A+/-1A  9A+/-1A
Boost Charging Voltage
14.2 ± 0.2 VDC 28.4  ± 0.2 VDC
Float Charging Voltage
13.7 ± 0.2 VDC 27.4  ± 0.2 VDC
  Protections
Protections
Battery Voltage Low (4 Auto Retries).
Over Load (6 Auto Retries)
Battery Over Charge, Over Temperature, Short Circuit (One Retry), Battery Deep Discharge  Protection
  Displays
Displays
AC Mains Voltage, UPS ON/OFF
Short Circuit, Overload, Battery Low, Load %
Mains ON/OFF,
Battery Charging/Charged/Low
  Weight and Dimensions
With Packing WXDXH in mm
390x340x130
Without Packing WXDXH in mm
310x260x90
Net Weight
3.4 Kg 4.25 Kg
Gross Weight
4.2Kg 5.10Kg
  General
Communication
4Pin Serial Interface for Calibration of Various Parameters
Operating Temperature Range
0Deg. To 45 Deg.
Relative Humidity
0-90% Non Condensing
 
 
Load Chart *

Load 650VA 850VA 1450VA
T.V
1 - - 1 - - 1 - -
Tube Light
4 4 - 6 5 - 10 8 -
Fan
3 4 - 4 5 - 7 9 -
Computers**
- - 4 - - 5 - - 10
 
Note: The Charging Current can be increased / decreased using the unique and “first-in- class” On Site Charging Rate Control OSCRCTM features.
 
**For Computer with 14” TFT monitors
   
 
 
Home          About Us          Products          Knowledge Center          Careers          Social Responsibility         Contact Us         Sitemap